Worcester Bosch · Greenstar Si Compact ErP

EA 261First safety timing error

This code applies to Greenstar 25Si Compact ErP, Greenstar 30Si Compact ErP. Fault codes narrow down the likely problem, but they do not replace a model-specific diagnosis.

What you can safely check

  1. Check whether another gas appliance works and whether a prepayment meter has credit.
  2. In freezing weather, visually check an accessible external condensate pipe for ice and follow the manufacturer's thawing guidance if applicable.
  3. Reset once only if the user manual permits it. If the code returns, arrange an engineer.

How an engineer may fix it

Test the gas supply and inlet pressure, ignition and ionisation components, condensate route, flue, gas valve and combustion settings; repair or replace the failed component.

Manufacturer source: Worcester Bosch — Greenstar Si Compact ErP Installation, Commissioning and Servicing Instructions (6 720 813 278). Checked 15 August 2026. The appliance manual and an engineer’s on-site diagnosis take precedence. Never remove the boiler case yourself.