Intergas · HRE, ECO RF & Rapid with iC3 PCB
1Temperature too high
This code applies to Combi Compact HRE 24/18, Combi Compact HRE 28/24, Combi Compact HRE 36/30, Combi Compact HRE 36/40, ECO RF, Rapid 25, Rapid 32. Fault codes narrow down the likely problem, but they do not replace a model-specific diagnosis.
What you can safely check
- Check the system pressure and make sure accessible radiator valves are open.
- Allow an overheated boiler to cool and reset once only if the user manual permits it.
- If the fault returns, stop resetting and arrange an engineer.
How an engineer may fix it
Diagnose water circulation, air locks, pump operation, valves, bypass, blockages, heat exchanger and temperature sensors; restore correct flow and test the safety controls.
Manufacturer source: Intergas — HRE, ECO RF & Rapid Parameters and Fault Codes (V10). Checked 15 August 2026. The appliance manual and an engineer’s on-site diagnosis take precedence. Never remove the boiler case yourself.